conductor_arm — deliberately authorise ONE unattended Conductor cold start, per node.
WHY THIS EXISTS
---------------
`autostart = true` in Run.conf used to mean "run on EVERY login, forever". On 2026-08-02 that fired
a cell nobody asked for on legacy-node: 144 minutes at 100x, no strategy loaded, zero corpus rows, and
nothing complained. Conductor v0.2.0 splits the two cases that both looked like autostart --
a RESUME of an in-flight bake still starts on its own, but a COLD START now needs a token that
EXPIRES and is CONSUMED on use. This writes that token.
python conductor_arm.py status # who is armed, and what for
python conductor_arm.py arm --node worker-1
python conductor_arm.py arm --node all --ttl 6
python conductor_arm.py disarm --node worker-3
WHAT MAKES THIS AN INTENT AND NOT ANOTHER STANDING FLAG
-------------------------------------------------------
* it EXPIRES (`ttlHours`, default 12) -- an arm you forgot about stops being permission;
* it is CONSUMED -- the Conductor renames it on use, so it cannot authorise the next restart;
* it PINS THE MANIFEST -- the token carries a fingerprint of Run.conf's job lines, so editing
what actually runs invalidates the arm. (Editing `heartbeatSec` does not, deliberately.)
⚠ Arming a node whose chart is not built is still a way to bake junk -- the token authorises, it
does not verify. That is what the productivity gate is for: it aborts a run that writes nothing.
Belt and braces, on purpose, because they fail differently.